WEDGE & CHAMBER CONSTRUCTIONAttenuating Structures In order to obtain a suitable sound environment, the anechoic chamber lining is installed in a proper noise isolating structure. This enclosure may be one of several types of construction built on an isolated floor, or floated on springs or other vibration isolation material.
Ventilation DesignThe ventilation system in the Eckel anechoic chamber is designed to maintain a uniform temperature, provide fresh air for humans and/or animals and facilitate proper combustion in air-consuming equipment. Ten to twelve air changes per hour of the free field volume will generally maintain uniform temperature and provide ample fresh air for humans or animals, while removing normal heat from lights, body radiation, and instrumentation. Installation ProcedureEckel anechoic linings are constructed according to a strictly supervised installation protocol. chamber linings are installed on roll formed wedge tracks attached to wall and ceiling surfaces by means of a "Z" bar mounting system. As wedges are erected, the space between the wedges is filled with light density compressible fiberglass or melamine foam. Instrumentation HangersEckel installs all hangers and brackets required to support instrumentation and test specimens. This includes a network of all necessary cables or wires. Eckel provides engineering or design data pertinent to the support of any type of equipment within an anechoic chamber upon request to the purchasers, and their consultants or engineers. Penetration SleevesElectrical power, wiring, and other services are introduced into the anechoic chamber by pipe sleeves that pass through the basic structure and wedges. Eckel Industries plans pipe penetrations carefully so that they enter the chamber through the valleys of the wedges and not the joints between the wedges. Lighting, ElectricalElectric services are always installed in compliance with local or UL-approved regulations. Electric light, conduits, and outlets usually penetrate the structure through the wedge valleys and terminate at that point with the appropriate outlet or fixture. Vibration Isolation
Reverberation Rooms
Other Available FeaturesEckel offers RF shielding, temperature and humidity control and other special features depending on client needs. Fiberglass cloth cover option protects against fiber migration, especially where the chamber will be incorporated into a wind tunnel test configuration.
For more information, fill out an Eckel Anechoic Chamber Check List
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Tel: +44 (0) 1276 471199 - Fax: +44 (0) 1276 453333
Home - Products
- Projects - Contacts
- Enquiry - Recruitment |